Reasons for abnormal cylinder movement and treatment measures
All categories

内页左边入口

Reasons for abnormal cylinder movement and treatment measures

(Summary description)

Reasons for abnormal cylinder movement and treatment measures

(Summary description)

Information
Reasons Measures
•  The pump is not flowing enough.  
•  The relief valve is not working properly.  
•  The remote port of the relief valve is open.  
•  Valve and cylinder components such as internal leakage is too large.  
•  The oil returns to the tank through a valve in the system.  
•  There is an incorrect aperture in the oil distribution pan.  
•  The flow control valve is poorly adjusted and not working properly.  
•  Load is below rating or frictional resistance is reduced by continuous operation.  
•  Air leakage from the accumulator.  
•  Throttling effect changes due to oil temperature changes.
Check the amount of oil leaking from each component, as well as the viscosity and temperature of the oil, and then take appropriate measures to deal with it.  
Check the action of each valve and correct the bad working condition.  
Check and repair the oil distribution pan.  
Changing the setting value to correct the abnormal working condition.
Fix the leak and then inflate.  
Install an oil temperature control device and a temperature compensated flow control valve.