Flow control valve troubleshooting
- Categories:Technical Support
- Author:
- Origin:
- Time of issue:2020-07-06 16:53
- Views:
(Summary description)
Flow control valve troubleshooting
(Summary description)
- Categories:Technical Support
- Author:
- Origin:
- Time of issue:2020-07-06 16:53
- Views:
Information
Failure | Reasons | Treatment |
Pressure compensation device not working properly | • The piston is clogged with dust. • Sleeve small hole clogged. • Inlet and outlet pressure difference is too small. | Disassembled for cleaning. Remove for cleaning. Use more than the specified pressure differential. |
Flow adjustment shaft (round shaft with eccentric groove) does not work | • The adjusting shaft is clogged with ash. • The secondary pressure is too high when using the throttling method in the oil inlet circuit. • In the scale range below the opening point, the primary pressure is high. | Remove for removal. Lower the pressure and then investigate. Do not use a parameter that is lower than the minimum regulated flow rate specified in the product, lower the pressure and adjust again. |
Rising dial (no such fault in the non-external oil drain form) | • Drain line clogged. • Oil drain hole has back pressure. | Clean the clogged line and separate it from the drain lines of the other valves. When the oil tank is higher than the valve, use a non-discharge type valve when there is a drop pressure head. |